4,679 research outputs found

    Light Absorption by Suspended Particles in the Red Sea: Effect of Phytoplankton Community Size Structure and Pigment Composition

    Get PDF
    The light absorption properties of phytoplankton (aph(λ)) and non-algal particles (anap(λ)) associated with phytoplankton pigments were analyzed across the Red Sea, in the upper 200 m depth, between October 2014 and August 2016. The contribution by non-algal particles to the total particulate light absorption (aph(λ)+ anap(λ)) was highly variable (23 ± 17% at 440 nm) and no relationship between anap(440) and chlorophyll a concentration, [TChl a], was observed. Phytoplankton specific phytoplankton absorption coefficients at 440 and 676 nm for a given [TChl a], aph*(440) and aph*(676), were slightly higher than those derived from average relationships for open ocean waters within the surface layer as well as along the water column. Variations in the concentration of photosynthetic and photoprotective pigments were noticeable by changes in phytoplankton community size structure as well as in aph*(λ). This study revealed that a higher proportion of picophytoplankton and an increase in photoprotective pigments (mainly driven by zeaxanthin) tended to be responsible for the higher aph*(λ) values found in the Red Sea as compared to other oligotrophic regions with similar [TChl a]. Understanding this variability across the Red Sea may help improve the accuracy of biogeochemical parameters, such as [TChl a], derived from in situ measurements and ocean color remote sensing at a regional scale

    Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes

    Get PDF
    BACKGROUND We sought to compare uterine cervical electrical impedance spectroscopy measurements employing two probes of different sizes, and to employ a finite element model to predict and compare the fraction of electrical current derived from subepithelial stromal tissue. METHODS Cervical impedance was measured in 12 subjects during early pregnancy using 2 different sizes of the probes on each subject. RESULTS Mean cervical resistivity was significantly higher (5.4 vs. 2.8 Ωm; p < 0.001) with the smaller probe in the frequency rage of 4–819 kHz. There was no difference in the short-term intra-observer variability between the two probes. The cervical impedance measurements derived in vivo followed the pattern predicted by the finite element model. CONCLUSION Inter-electrode distance on the probes for measuring cervical impedance influences the tissue resistivity values obtained. Determining the appropriate probe size is necessary when conducting clinical studies of resistivity of the cervix and other human tissues

    Targeting subchondral bone mesenchymal stem cell activities for intrinsic joint repair in osteoarthritis

    No full text
    Osteoarthritis (OA) is a common age-related disease with complex pathophysiology. It is characterized by wide-ranging tissue damage and ultimate biomechanical failure of the whole joint. However, signs of tissue adaptation and attempted repair responses are evident in OA-affected osteochondral tissues. Highlighted in this review article is the role of bone-resident mesenchymal stem cells (MSCs) in these bone remodeling responses, and a proposal that targeting MSC activities in OA subchondral bone could represent a novel approach for intrinsic joint regeneration in OA. The development of these therapies will require better understanding of MSC proliferation, migration and differentiation patterns in relation to OA tissue damage and further clarification of the molecular signaling events in these MSCs during disease progression

    Limited versus full sternotomy for aortic valve replacement

    Get PDF
    Copyright \ua9 2023 The Cochrane Collaboration. Published by John Wiley &amp; Sons, Ltd. BACKGROUND: Aortic valve disease is a common condition easily treatable with cardiac surgery. This is conventionally performed by opening the sternum (\u27median sternotomy\u27) and replacing the valve under cardiopulmonary bypass. Median sternotomy is well tolerated, but as less invasive options become available, the efficacy of limited incisions has been called into question. In particular, the effects of reducing the visibility and surgical access have raised safety concerns with regard to the placement of cannulae, venting of the heart, epicardial wire placement, and de-airing of the heart at the end of the procedure. These difficulties may increase operating times, affecting outcome. The benefits of smaller incisions are thought to include decreased pain; improved respiratory mechanics; reductions in wound infections, bleeding, and need for transfusion; shorter intensive care stay; better cosmesis; and a quicker return to normal activity. This is an update of a Cochrane review first published in 2017, with seven new studies. OBJECTIVES: To assess the effects of minimally invasive aortic valve replacement via a limited sternotomy versus conventional aortic valve replacement via median sternotomy in people with aortic valve disease requiring surgical replacement. SEARCH METHODS: We performed searches of CENTRAL, MEDLINE and Embase from inception to August 2021, with no language limitations. We also searched two clinical trials registries and manufacturers\u27 websites. We reviewed references of primary studies to identify any further studies of relevance. SELECTION CRITERIA: We included randomised controlled trials comparing aortic valve replacement via a median sternotomy versus aortic valve replacement via a limited sternotomy. We excluded trials that performed other minimally invasive incisions such as mini-thoracotomies, port access, transapical, transfemoral or robotic procedures. Although some well-conducted prospective and retrospective case-control and cohort studies exist, these were not included in this review. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trial papers to extract data, assess quality, and identify risk of bias. A third review author provided arbitration where required. We determined the certainty of evidence using the GRADE methodology and summarised results of patient-relevant outcomes in a summary of findings table. MAIN RESULTS: The review included 14 trials with 1395 participants. Most studies had at least two domains at high risk of bias. We analysed 14 outcomes investigating the effects of minimally invasive limited upper hemi-sternotomy on aortic valve replacement as compared to surgery performed via full median sternotomy. Upper hemi-sternotomy may have little to no effect on mortality versus full median sternotomy (risk ratio (RR) 0.93, 95% confidence interval (CI) 0.45 to 1.94; 10 studies, 985 participants; low-certainty evidence). Upper hemi-sternotomy for aortic valve replacement may increase cardiopulmonary bypass time slightly, although the evidence is very uncertain (mean difference (MD) 10.63 minutes, 95% CI 3.39 to 17.88; 10 studies, 1043 participants; very low-certainty evidence) and may increase aortic cross-clamp time slightly (MD 6.07 minutes, 95% CI 0.79 to 11.35; 12 studies, 1235 participants; very low-certainty evidence), although the evidence is very uncertain. Most studies had at least two domains at high risk of bias. Postoperative blood loss was probably lower in the upper hemi-sternotomy group (MD -153 mL, 95% CI -246 to -60; 8 studies, 767 participants; moderate-certainty evidence). Low-certainty evidence suggested that there may be no change in pain scores by upper hemi-sternotomy (standardised mean difference (SMD) -0.19, 95% CI -0.43 to 0.04; 5 studies, 649 participants). Upper hemi-sternotomy may result in little to no difference in quality of life (MD 0.03 higher, 95% CI 0 to 0.06 higher; 4 studies, 624 participants; low-certainty evidence). Two studies reporting index admission costs concluded that limited sternotomy may be more costly at index admission in the UK National Health Service (MD 1190 GBP more, 95% CI 420 GBP to 1970 GBP, 2 studies, 492 participants; low-certainty evidence). AUTHORS\u27 CONCLUSIONS: The evidence was of very low to moderate certainty. Sample sizes were small and underpowered to demonstrate differences in some outcomes. Clinical heterogeneity was also noted. Considering these limitations, there may be little to no effect on mortality. Differences in extracorporeal support times are uncertain, comparing upper hemi-sternotomy to full sternotomy for aortic valve replacement. Before widespread adoption of the minimally invasive approach can be recommended, there is a need for a well-designed and adequately powered prospective randomised controlled trial. Such a study would benefit from also performing a robust cost analysis. Growing patient preference for minimally invasive techniques merits thorough quality of life analyses to be included as end points, as well as quantitative measures of physiological reserve

    Identification and Characterization of MicroRNAs in Asiatic Cotton (Gossypium arboreum L.)

    Get PDF
    To date, no miRNAs have been identified in the important diploid cotton species although there are several reports on miRNAs in upland cotton. In this study, we identified 73 miRNAs, belonging to 49 families, from Asiatic cotton using a well-developed comparative genome-based homologue search. Several of the predicted miRNAs were validated using quantitative real time PCR (qRT-PCR). The length of miRNAs varied from 18 to 22 nt with an average of 20 nt. The length of miRNA precursors also varied from 46 to 684 nt with an average of 138 ±120 nt. For a majority of Asiatic cotton miRNAs, there is only one member per family; however, multiple members were identified for miRNA 156, 414, 837, 838, 1044, 1533, 2902, 2868, 5021 and 5142 families. Nucleotides A and U were dominant, accounted for 62.95%, in the Asiatic cotton pre-miRNAs. The Asiatic cotton pre-miRNAs had high negative minimal folding free energy (MFE) and adjusted MFE (AMFE) and high MFE index (MFEI). Many miRNAs identified in Asiatic cotton suggest that miRNAs also play a similar regulatory mechanism in diploid cotton

    Training emergency services’ dispatchers to recognise stroke: an interrupted time-series analysis

    Get PDF
    Background: Stroke is a time-dependent medical emergency in which early presentation to specialist care reduces death and dependency. Up to 70% of all stroke patients obtain first medical contact from the Emergency Medical Services (EMS). Identifying ‘true stroke’ from an EMS call is challenging, with over 50% of strokes being misclassified. The aim of this study was to evaluate the impact of the training package on the recognition of stroke by Emergency Medical Dispatchers (EMDs). Methods: This study took place in an ambulance service and a hospital in England using an interrupted time-series design. Suspected stroke patients were identified in one week blocks, every three weeks over an 18 month period, during which time the training was implemented. Patients were included if they had a diagnosis of stroke (EMS or hospital). The effect of the intervention on the accuracy of dispatch diagnosis was investigated using binomial (grouped) logistic regression. Results: In the Pre-implementation period EMDs correctly identified 63% of stroke patients; this increased to 80% Post-implementation. This change was significant (p=0.003), reflecting an improvement in identifying stroke patients relative to the Pre-implementation period both the During-implementation (OR=4.10 [95% CI 1.58 to 10.66]) and Post-implementation (OR=2.30 [95% CI 1.07 to 4.92]) periods. For patients with a final diagnosis of stroke who had been dispatched as stroke there was a marginally non-significant 2.8 minutes (95% CI −0.2 to 5.9 minutes, p=0.068)reduction between Pre- and Post-implementation periods from call to arrival of the ambulance at scene. Conclusions: This is the first study to develop, implement and evaluate the impact of a training package for EMDs with the aim of improving the recognition of stroke. Training led to a significant increase in the proportion of stroke patients dispatched as such by EMDs; a small reduction in time from call to arrival at scene by the ambulance also appeared likely. The training package has been endorsed by the UK Stroke Forum Education and Training, and is free to access on-line

    Particulate Scattering and Backscattering in Relation to the Nature of Particles in the Red Sea

    Get PDF
    This is the final version. Available on open access from the American Geophysical Union via the DOI in this recordData Availability Statement: The data presented in this study are archived in KAUST repository (https://doi.org/10.25781/KAUST‐PSDX7).European Space AgencyKing Abdullah University of Science and Technology (KAUST), Kingdom of Saudi ArabiaSimons Foundatio

    Research Article

    Get PDF
    Mixed modeling and sample size calculations for identifying housekeeping gene

    Comparative uptake of fluoride ion into enamel from various topical fluorides in vitro

    Get PDF
    The document attached has been archived with permission from the Australian Dental Association (8 March 2008). An external link to the publisher’s copy is included.Background: There are many forms of topical fluoride available today, making the decision as to which is most effective to manage the immediate caries risk problem at hand, very difficult. The objective of this project was to determine the concentration and pattern of fluoride ion uptake into enamel from a variety of categories of topical fluoride recently available in Australia. Methods: Extracted, intact molar teeth were sectioned to provide six plates of smooth surface enamel. Windows of enamel 2 x 6mm were exposed to a variety of topical fluorides for periods simulating those used in vivo. Following drying, the slates of enamel were exposed to 2ml of 0.1M HCl as a chemical biopsy agent for incremental periods of time. The concentrations of fluoride ion in the biopsy solutions for both test and background (control) slates of enamel were determined directly using a fluoride combination selective electrode in conjunction with a high impedance pH meter. Cumulative amounts of fluoride were determined for each topical fluoride agent. Results: The concentrations of fluoride ion taken up into enamel were generally proportional to those present in each agent. However, those from APF gel greatly exceeded the amounts taken up from NaF gel. Also, the concentrations taken up from some of the highly concentrated metal fluorides were surprisingly low. Prior etching of enamel increased uptake and prolonged application of APF gel provided no extra benefit. Conclusions: Some topical fluorides, e.g., APF gel, provided a greatly increased uptake and to a greater depth than other self-application products. However, the frequency of its use should be considered with caution where patients have glassbased restorations.N Pai, J McIntyre, N Tadic and C Laparidi
    corecore